PERMIT APPLICATION COMMON
Where on your property are you working?:
Onsite + ROW
Is work in the right-of-way (street or alley) required?:
Yes
Choose the Primary Property Use:
Single Family/Duplex
Project Value:
600000
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
01/11/2025
Permit Issued Date:
08/27/2025
Permit Remarks:
Pin pile shoring included.
FLOATING RESIDENCE INFO
Is this building a Floating Residence?:
No
CONSTRUCTION VALUATION INFO
Intake Value: New:
618766
Intake Value: Alteration:
0
Total Intake Value:
618766
Issue Value: New:
618766
Issue Value: Alteration:
0
Total Issued Value:
618766
BUILDING CODE INFO
What building code was used for your design?:
2021 SBC (Struct) and SRC (Arch)
Action Type:
New
Number of Proposed Building Stories:
3
Number of Proposed Below-Grade Building Stories:
1
Number of Mezzanines:
0
Is this a high-rise?:
No
Will you change the building use or occupancy?:
No
Will your application include a new standard plan?:
No
Is a certificate of occupancy required?:
No
GROUND DISTURBANCE
Is your development site in an environmentally critical area (ECA)?:
Yes
New and Replaced Hard Surface > 750 sq ft?:
Yes
Are you doing more than 2,000 square feet of earth disturbance?:
Yes
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
Foundation Type:
Spread Footing
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
2
Curb Cut Size and Location:
Two standard residential curb cuts 10' wide. One to be located along 3rd Ave N 6'-6" from north property line, and the other to be located along Fulton Street 28'-11" from the west property line.
PARKING
# of Proposed Onsite Parking:
3
Tenant Relocation Assistance
Are there residential (non-commercial) tenants/renters currently living in the property? :
No
ENERGY CODE
Compliance Category:
Residential
Compliance Path:
Total UA Alternative
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Residential:
Electric Heat Pump
SIDE SEWER INFORMATION
Related New Construction Project:
7058368
Temporary Dewatering for Construction:
No
Pipe Lining in the Right-of-Way:
No
DRAINAGE INFORMATION
Drainage Type of Work:
New
Number of Other New Drainage Connections:
1
Number of Drainage New/Replaced/Repair Pumps:
1
Flow Control Type:
No Control
Flow Control Standard:
None
Treatment Standard Type:
No Treatment
Discharge Point:
Combined System
Discharge Point Other Type:
(3rd Ave N)
Total Disturbed Area:
4002
New Impervious Surface:
947
New Plus Replaced Impervious Surface:
1775
Total Volume Managed by On-Site Stormwater Management (gallons):
20264
Total Area Requiring Soil Amendment:
1280
SANITARY INFORMATION
Sanitary Type of Work:
New
Number of New Dwelling Units:
3
Reuse Existing Side Sewer System:
No
CONTRACTOR DISCLOSURE
Who will be performing all the work?:
Owner/Lessee
I have submitted an application for a building permit from the City of Seattle. I believe the work authorized by this permit is exempt from having a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work.:
Yes
SIDE SEWER INFORMATION
Curb Crossing and/or Staging:
Yes
Excavation:
Yes
SANITARY INFORMATION
Number of New Sewer Connections to the Main:
1