Application Information
|
PERMIT APPLICATION COMMON
Where on your property are you working?:
Entire parcel
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Multifamily
Project Value:
80000000
CONSTRUCTION VALUATION INFO
Intake Value: New:
30837574
Intake Value: Alteration:
2115708
Total Intake Value:
32953282
Issue Value: New:
31350000
Issue Value: Alteration:
1025000
Total Issued Value:
32375000
INTERDEPARTMENTAL COORDINATION
SDOT Concept Approval:
Yes
SDOT Permit Accepted:
Yes
SDOT SIP PM:
YM
BUILDING CODE INFO
What building code was used for your design?:
2018 SBC
Is this a substantial alteration?:
Yes
Are you changing the envelope?:
Yes
Action Type:
New
Number of Existing Building Stories:
1
Number of Existing Below-Grade Building Stories:
0
Number of Proposed Building Stories:
8
Number of Proposed Below-Grade Building Stories:
2
Number of Mezzanines:
0
Is this a high-rise?:
No
Will you change the building use or occupancy?:
Yes
Main Existing Use of Building:
Business
Existing Occupancy:
B Office
Will your application include a new standard plan?:
No
Is a certificate of occupancy required?:
Yes
GROUND DISTURBANCE
Is the ground disturbance in an environmentally critical area?:
No
New and Replaced Hard Surface > 750 sq ft?:
Yes
What is the amount of ground disturbance?:
Yes
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
Foundation Type:
Basement
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
10/17/2024
Permit Remarks:
Scope includes sub-alts to Landmarked Shannon and Wilson office building.
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
1
Curb Cut Size and Location:
SUSIP0000853
PARKING
Number of Existing Onsite Parking Spaces:
22
Number of Existing Offsite Parking Spaces:
0
Number of Existing Accessible Parking Spaces:
2
Number of Proposed Onsite Parking Spaces:
104
Number of Proposed Offsite Parking Spaces:
0
Number of Proposed Accessible Parking Spaces:
8
Number of Existing Bicycle Parking Spots:
0
Number of Proposed Bicycle Parking Spots:
62
Tenant Relocation Assistance
Residential Unit Occupancy:
Vacant Land
Are there residential (non-commercial) tenants/renters currently living in the property? :
No
Will the scope of the proposed project displace the tenants/renters?:
No
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
Sprinklers Meet NFPA 13R:
No
Partial Fire Protection System:
No
Fire Alarm:
Yes
Other Fire Protection System:
No
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
Yes
Elevator Pressurization:
Yes
Stairway Pressurization:
Yes
Smoke Removal System:
No
Accessible Elevator Egress:
Yes
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
Yes
MECHANICAL DUCTWORK LOCATION
Is there any equipment inside?:
Yes
Is there any rooftop equipment? :
Yes
ENERGY CODE
Is any portion of the building semi-heated or unheated?:
Yes
Compliance Category:
Commercial
Compliance Path:
Total Building Performance (TBP)
Is there a commercial kitchen hood exhaust system?:
No
Is there a fume hood?:
No
Is there a spray paint booth?:
No
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Residential:
Electric Heat Pump
Heating Fuel Type Proposed: Non-Residential:
Electric Heat Pump
SPECIAL PROGRAMS
Is this project receiving Opportunity Zone Funds?:
No
CONTRACTOR DISCLOSURE
Who will be performing all the work?:
Licensed Contractor
Contractor License:
COMPAGC933B4
|
Other Information
|
HOUSING UNITS |
Type of Housing Unit: Apartment Number of Existing Units: 8 Number of Removed Units: 8 Number of Added Units: 180 Number of Sleeping Rooms: 226 |
|
BUILDING USE & OCCUPANCY |
Floor or Area: Level 2 exist Floor Area (square feet): 2105 Occupancy Group: A-2 Restaurant Type of Construction: Type IA Sprinkler Standard: Full System |
Floor or Area: Levels 1-2 Floor Area (square feet): 28233 Occupancy Group: R-2 Apartment/Condominium Type of Construction: Type IA Sprinkler Standard: Full System |
Floor or Area: Levels 3-8 Floor Area (square feet): 96041 Occupancy Group: R-2 Apartment/Condominium Type of Construction: Type IIIA Sprinkler Standard: Full System |
Floor or Area: Levels 2-5 walkup Floor Area (square feet): 4976 Occupancy Group: R-2 Apartment/Condominium Type of Construction: Type VA Sprinkler Standard: Full System |
Floor or Area: Level 2 exist Floor Area (square feet): 2614 Occupancy Group: Other B Occupancy Type of Construction: Type IA Other Occupancy Type: Exercise and gaming rooms Sprinkler Standard: Full System |
Floor or Area: Level 2 exist Floor Area (square feet): 4564 Occupancy Group: B Office Type of Construction: Type IA Sprinkler Standard: Full System |
Floor or Area: Levels P2-P1 Floor Area (square feet): 37499 Occupancy Group: S-2 Parking Garage - Enclosed Type of Construction: Type IA Sprinkler Standard: Full System |
Floor or Area: Levels P2-P1 Floor Area (square feet): 1867 Occupancy Group: S-1 Storage - Moderate Hazard Type of Construction: Type IA Sprinkler Standard: Full System |
|
REQUIRED DOCUMENTS |
Must this be recorded?: No |
Must this be recorded?: No |
Must this be recorded?: No |
Must this be recorded?: No |
Must this be recorded?: No |
Must this be recorded?: No Description: DON Approval Letter |
Must this be recorded?: No |
Must this be recorded?: No Description: Balconies |
Must this be recorded?: No |
Must this be recorded?: No |
Must this be recorded?: No Description: intumescent coating for steel framing |
|
FENESTRATION |
Occupancy Group: Multifamily Residential Fenestration Type: Opaque Door U Max: 0.37 |
Occupancy Group: Multifamily Residential Fenestration Type: Vertical Glazing U Max: 0.26 SHGC Max: 0.29 Comments: non-metal |
Occupancy Group: Multifamily Residential Fenestration Type: Vertical Glazing U Max: 0.28 SHGC Max: 0.38 Comments: sliding doors |
Occupancy Group: Multifamily Residential Fenestration Type: Vertical Glazing U Max: 0.34 SHGC Max: 0.38 Comments: storefront |
Occupancy Group: Multifamily Residential Fenestration Type: Vertical Glazing U Max: 0.6 SHGC Max: 0.38 Comments: entrance door |
|
OPAQUE ELEMENTS |
Occupancy Group: Multifamily Residential Insulation Assembly: Floor: Mass Cavity R-Value: 30 Comments: F2? F3 |
Occupancy Group: Multifamily Residential Insulation Assembly: Roof or Ceiling Single Rafter Cavity R-Value: 30 Cont R-Value: 20 Comments: R1, R2 |
Occupancy Group: Multifamily Residential Insulation Assembly: Wall: Above Grade Mass Cont R-Value: 0 Comments: C1 |
Occupancy Group: Multifamily Residential Insulation Assembly: Wall: Above Grade Wood Framing Cavity R-Value: 21 Comments: E1, E2, E4 |
Occupancy Group: Multifamily Residential Insulation Assembly: Wall: Below Grade Cont R-Value: 0 Comments: c1 |
|
PROJECT PHASES |
Instructions: Select the phase you are attempting to update.: 1 Shoring/Excavation: No Foundations: Yes Structure to Grade: Yes Base Structure: Yes Super Structure: Yes Architectural Shell and Core: No Architectural Full Occupancy: No Description of Scope: Foundations through Super-Structure of residential (Full Structural Completion) Anticipated Submittal Date: March 2024 Intake Date: 10/17/2024 Status: In Review Does this project contain any equipment that will store electricity for standby or emergency power, an uninterruptable power supply, load shedding, load sharing, or has similar capabilities that provides power to a building?: No |
Instructions: Select the phase you are attempting to update.: 2 Shoring/Excavation: No Foundations: No Structure to Grade: No Base Structure: No Super Structure: No Architectural Shell and Core: Yes Architectural Full Occupancy: No Description of Scope: Architectural Shell and Core through Architectural Occupancy of residential portions (Full Architectural Completion of residential) Anticipated Submittal Date: December 2025 Intake Date: 12/15/2025 Status: In Review Does this project contain any equipment that will store electricity for standby or emergency power, an uninterruptable power supply, load shedding, load sharing, or has similar capabilities that provides power to a building?: No |
Instructions: Select the phase you are attempting to update.: 3 Shoring/Excavation: No Foundations: No Structure to Grade: No Base Structure: No Super Structure: Yes Architectural Shell and Core: Yes Architectural Full Occupancy: Yes Description of Scope: Seismic retrofit/structural completion and full architectural completion of non-residential existing building Anticipated Submittal Date: January 2026 Intake Date: 02/02/2026 Status: In Review Does this project contain any equipment that will store electricity for standby or emergency power, an uninterruptable power supply, load shedding, load sharing, or has similar capabilities that provides power to a building?: No |
|
RESIDENTIAL ENERGY EQUIP SIZES |
Unit ID: 106,206,306,406,506,606,706,806 Allowance Factor: 1.25 Minimum BTUs: 3280 |
Unit ID: 116,216,218,316,318,416,418,516,518,616,618,716,718,816,818 Minimum BTUs: 2980 |
Unit ID: 110,111,112,210,211,212,310,311,312,410,411,412 Minimum BTUs: 3470 |
Unit ID: 117,217,317,417,517,617,717,817 Minimum BTUs: 3480 |
Unit ID: 510,511,512,610,611,612,710,711,712,810,811,812 Minimum BTUs: 3470 |
Unit ID: 510,511,512,610,611,612,710,711,712,810,811,812 Minimum BTUs: 3470 |
Unit ID: 301,322,401,422,501,522,601,622,701,722 Minimum BTUs: 3690 |
Unit ID: 220 Minimum BTUs: 3610 |
Unit ID: 113,213,313,413,513,613,713,813 Minimum BTUs: 4990 |
Unit ID: 109,209,309,409,509,609,709,809 Minimum BTUs: 5630 |
Unit ID: 108,208,308,408,508,608,708,808 Minimum BTUs: 3440 |
Unit ID: 107,207,307,407,507,607,707,807 Minimum BTUs: 4050 |
Unit ID: 114,214,314,414,514,614,714,814 Minimum BTUs: 3230 |
Unit ID: 321,421,521,621,721 Minimum BTUs: 3300 |
Unit ID: 115,215,315,415,615,715,815 Minimum BTUs: 3870 |
Unit ID: 320,420,520,620,720 Minimum BTUs: 4020 |
Unit ID: 303,403,503,603,703 Minimum BTUs: 4060 |
Unit ID: 302,402,502,602,702 Minimum BTUs: 3370 |
Unit ID: 105,205,305,405505,605,705,805 Minimum BTUs: 5820 |
Unit ID: 304,404,504,604,704 Minimum BTUs: 8230 |
Unit ID: 121,122,,123,221,222,223 Minimum BTUs: 5260 |
Unit ID: 801,821 Minimum BTUs: 5360 |
Unit ID: 820 Minimum BTUs: 9700 |
Unit ID: 219,319,419,519,619,719 Minimum BTUs: 7260 |
Unit ID: walkup unit 225,226,325,326,425,426,525,526 Minimum BTUs: 6670 |
|
Parcel Information
|
Development Site Parcel:DV0352418 * | | |
|
|