PERMIT APPLICATION COMMON
Where on your property are you working?:
24,135 SF OF RENOVATION OF THE INTERIOR ONLY ON THE FIRST FLOOR IN THE 02-25 BUILDING. DEMOLITION WILL INCLUDE THE REMOVAL OF EXISTING WORKSTATIONS, FLOOR/CEILING MATERIALS AND PORTIONS OF THE HVAC AND ELECTRICAL SYSTEMS. TENANT IMPROVEMENT WILL INCLUDE NEW WALLS, CEILINGS AND FLOOR FINISHES THROUGHOUT. EXISTING MECHANICAL, HVAC AND FIRE PROTECTION SYSTEMS WILL BE MODIFIED TO SUPPORT THE NEW LAYOUT UNDER SEPARATE PERMIT. ELECTRICAL POWER, LIGHTING, COMMUNICATION AND DATA SYSTEMS WILL BE MODIFIED TO SUPPORT THE NEW LAYOUT UNDER SEPARATE PERMIT.
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Commercial
Project Value:
6634000
PERMIT TRACKING COMMON
Review Level:
Full +
Application Completed Date:
03/16/2023
Permit Issued Date:
08/01/2023
Inspections Completed Date:
02/29/2024
FLOATING RESIDENCE INFO
Is this building a Floating Residence?:
No
CONSTRUCTION VALUATION INFO
Intake Value: New:
0
Intake Value: Alteration:
6634000
Total Intake Value:
6634000
Issue Value: New:
0
Issue Value: Alteration:
6634000
Total Issued Value:
6634000
BUILDING CODE INFO
What building code was used for your design?:
2018 SEBC
Is this a substantial alteration?:
No
Are you changing the envelope?:
No
Action Type:
Add/Alt
Number of Existing Building Stories:
5
Number of Existing Below-Grade Building Stories:
1
Number of Proposed Building Stories:
5
Number of Proposed Below-Grade Building Stories:
1
Number of Mezzanines:
0
Is this a high-rise?:
No
Will you change the building use or occupancy?:
No
Main Existing Use of Building:
Business
Existing Occupancy:
B Office
Will your application include a new standard plan?:
No
Is a certificate of occupancy required?:
No
GROUND DISTURBANCE
Is your development site in an environmentally critical area (ECA)?:
No
New and Replaced Hard Surface > 750 sq ft?:
No
Are you doing more than 2,000 square feet of earth disturbance?:
No
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
0
Curb Cut Size and Location:
n/a
PARKING
# of Existing Onsite Parking:
0
# of Proposed Onsite Parking:
0
# of Existing Bicycle Parking Spots:
0
# of Proposed Bicycle Parking Spots:
0
Tenant Relocation Assistance
Residential Unit Occupancy:
No Residential Units on Property
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
Sprinklers Meet NFPA 13R:
No
Partial Fire Protection System:
Yes
Fire Alarm:
Yes
Other Fire Protection System:
No
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Is any portion of the building semi-heated or unheated?:
Yes
Compliance Category:
Commercial
Compliance Path:
Prescriptive
Is there a commercial kitchen hood exhaust system?:
No
Is there a fume hood?:
No
Is there a spray paint booth?:
No
Describe any other mechanical systems to be installed as part of this project.:
None under this permit
CONTRACTOR DISCLOSURE
Who will be performing all the work?:
Licensed Contractor
Contractor License:
WASHIPC906BJ