PERMIT APPLICATION COMMON
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Commercial
Project Value:
100000000
CONSTRUCTION VALUATION INFO
Intake Value: New:
112209560
Intake Value: Alteration:
0
Total Intake Value:
112209560
Issue Value: New:
112209560
Issue Value: Alteration:
0
Total Issued Value:
112209560
BUILDING CODE INFO
What building code was used for your design?:
2018 SBC
Action Type:
New
Number of Existing Building Stories:
0
Number of Existing Below-Grade Building Stories:
0
Number of Proposed Building Stories:
49
Number of Proposed Below-Grade Building Stories:
4
Number of Mezzanines:
0
Is this a high-rise?:
Yes
Is a certificate of occupancy required?:
Yes
GROUND DISTURBANCE
Is the ground disturbance in an environmentally critical area?:
Yes
New and Replaced Hard Surface > 750 sq ft?:
Yes
What is the amount of ground disturbance?:
Yes
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
02/15/2023
Permit Issued Date:
09/02/2025
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
1
Curb Cut Size and Location:
One curb cut along John Street on the south side of the turnaround cul-de-sac.
PARKING
Number of Proposed Onsite Parking Spaces:
60
Number of Proposed Offsite Parking Spaces:
0
Number of Proposed Accessible Parking Spaces:
0
Number of Existing Bicycle Parking Spots:
0
Number of Proposed Bicycle Parking Spots:
400
Tenant Relocation Assistance
Residential Unit Occupancy:
Residential Units on Property Not Affected by Scope
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
Sprinklers Meet NFPA 13R:
No
Partial Fire Protection System:
No
Fire Alarm:
Yes
Other Fire Protection System:
No
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
Yes
Elevator Pressurization:
Yes
Stairway Pressurization:
Yes
Smoke Removal System:
No
Accessible Elevator Egress:
Yes
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
Yes
Mechanical System Scope:
central plan serving 3 buildings.
MECHANICAL DUCTWORK LOCATION
Is there any equipment inside?:
Yes
Is there any rooftop equipment? :
Yes
ENERGY CODE
Is any portion of the building semi-heated or unheated?:
Yes
Compliance Category:
Commercial
Compliance Path:
Total Building Performance (TBP)
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Residential:
Other
Heating Fuel Type Proposed: Non-Residential:
Other
Special Requirements:
heat recovery chiller and gas heating boiler shared a Central plan to service three buildings: 1120 Denny, 1120 John & 121 Boren.
SIDE SEWER INFORMATION
Related New Construction Project:
6905992
Curb Crossing and/or Staging:
Yes
Excavation:
Yes
Curb and Sidewalk Restoration?:
Yes
Roadway Restoration:
Yes
DRAINAGE INFORMATION
Drainage Type of Work:
New
Number of New Drainage Connections to the Main:
1
Flow Control Type:
Vault
Flow Control Standard:
Peak
Treatment Standard Type:
No Treatment
Discharge Point:
Combined System
Total Disturbed Area:
17155
New Impervious Surface:
0
New Plus Replaced Impervious Surface:
16681
Total Volume Managed by On-Site Stormwater Management (gallons):
112643
Total Area Requiring Soil Amendment:
474
SANITARY INFORMATION
Sanitary Type of Work:
New
Number of New Sewer Connections to the Main:
3
Number of New Connections to the Side Sewer:
3
Number of New Dwelling Units:
478
Reuse Existing Side Sewer System:
No
CONTRACTOR DISCLOSURE
Who will be performing all the work?:
Licensed Contractor
Contractor License:
ONNIBBA781MO