PERMIT APPLICATION COMMON
Where on your property are you working?:
We are not doing any construction, just land use change.
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Commercial
Project Value:
50000
PERMIT TRACKING COMMON
Review Level:
Full +
Application Completed Date:
02/03/2020
Permit Issued Date:
02/06/2025
Inspections Completed Date:
06/13/2025
Certificate of Occupancy Issued Date:
06/13/2025
FLOATING RESIDENCE INFO
Is this building a Floating Residence?:
No
CONSTRUCTION VALUATION INFO
Intake Value: New:
0
Intake Value: Alteration:
50000
Total Intake Value:
50000
Issue Value: New:
0
Issue Value: Alteration:
393082
Total Issued Value:
393082
BUILDING CODE INFO
What building code was used for your design?:
2015 SBC
Is this a substantial alteration?:
Yes
Are you changing the envelope?:
No
Action Type:
Add/Alt
Number of Existing Building Stories:
1
Number of Existing Below-Grade Building Stories:
0
Number of Proposed Building Stories:
0
Number of Proposed Below-Grade Building Stories:
0
Number of Mezzanines:
0
Is this a high-rise?:
No
Will you change the building use or occupancy?:
Yes
Main Existing Use of Building:
Factory and Industrial
Existing Occupancy:
F-1 Factory - Moderate Hazard
Will your application include a new standard plan?:
No
Is a certificate of occupancy required?:
Yes
GROUND DISTURBANCE
Is your development site in an environmentally critical area (ECA)?:
No
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
0
PARKING
# of Existing Onsite Parking:
4
Tenant Relocation Assistance
Residential Unit Occupancy:
No Residential Units on Property
WASTE DIVERSION
Waste Diversion Plan Required:
Yes
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
No
Sprinklers Meet NFPA 13R:
No
Partial Fire Protection System:
No
Fire Alarm:
No
Other Fire Protection System:
No
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Is any portion of the building semi-heated or unheated?:
Yes
Compliance Category:
Commercial
Compliance Path:
Component Performance
Is there a commercial kitchen hood exhaust system?:
No
Is there a fume hood?:
No
Is there a spray paint booth?:
No
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Non-Residential:
Unknown
Special Requirements:
Sub. Alt. #2, C503.8.3 #2.2 "disproportionality" exception used. onsite renewable using exception 1-10% HIGHER EFF. ON MECH EQUIPMENT
DRAINAGE INFORMATION
Number of Service Drain Lines Capped:
0
Drainage Type of Work:
Addition/Alteration
Number of New Drainage Connections to the Main:
0
Number of Other New Drainage Connections:
0
Number of Drainage New/Replaced/Repair Pumps:
0
Flow Control Type:
No Control
Flow Control Standard:
None
Treatment Standard Type:
No Treatment
Discharge Point:
Other
Discharge Point Other Type:
PPS and woodchips over amended soils
Total Disturbed Area:
5622
New Impervious Surface:
0
New Plus Replaced Impervious Surface:
1848
Total Volume Managed by On-Site Stormwater Management (gallons):
26854
Total Area Requiring Soil Amendment:
3774
SANITARY INFORMATION
Sanitary Type of Work:
None
Number of New Dwelling Units:
0
CONTRACTOR DISCLOSURE
Who will be performing all the work?:
Licensed Contractor
Contractor License:
RMILLMI871NH