PERMIT APPLICATION COMMON
Where on your property are you working?:
SCOPE OF WORK AT UPPER LEVEL:
NON STRUCTURAL INTERIOR ALTERATION TO THE
EXISTING MASTER BEDROOM, BATHROOM AND
CLOSET.
SCOPE OF WORK AT WEST PATIO:
EXTERIOR ALTERATION TO THE EXISTING SINGLE
FAMILY RESIDENCES PATIO TO INCLUDE A NEW
PLUNGE POOL.
SCOPE OF WORK AT SHOP:
NON STRUCTURAL INTERIOR ALTERATION TO
EXISTING SHOP AND COVERED OUTDOOR KITCHEN
ADDITION.
MECHANICAL, ELECTRICAL AND PLUMBING TO BE
DESIGN BUILD AND PERMITTED SEPARATELY.
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Single Family/Duplex
Project Value:
400000
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
02/21/2020
Permit Issued Date:
09/02/2021
Inspections Completed Date:
08/06/2024
CONSTRUCTION VALUATION INFO
Intake Value: New:
0
Intake Value: Alteration:
400000
Total Intake Value:
400000
Issue Value: New:
0
Issue Value: Alteration:
400000
Total Issued Value:
400000
BUILDING CODE INFO
What building code was used for your design?:
2015 SRC
Is this a substantial alteration?:
No
Are you changing the envelope?:
No
Action Type:
Add/Alt
Number of Existing Building Stories:
3
Number of Existing Below-Grade Building Stories:
1
Number of Proposed Building Stories:
0
Number of Proposed Below-Grade Building Stories:
0
Number of Mezzanines:
0
Is this a high-rise?:
No
Will you change the building use or occupancy?:
No
Main Existing Use of Building:
Residential
Existing Occupancy:
R-3 Single Family Dwelling
Will your application include a new standard plan?:
No
Is a certificate of occupancy required?:
No
GROUND DISTURBANCE
Is your development site in an environmentally critical area (ECA)?:
Yes
New and Replaced Hard Surface > 750 sq ft?:
Yes
Are you doing more than 2,000 square feet of earth disturbance?:
No
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
Foundation Type:
Basement
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
0
Curb Cut Size and Location:
Not Applicable
PARKING
# of Existing Onsite Parking:
2
# of Existing Offsite Parking:
0
# of Existing Accessible Parking:
0
# of Proposed Onsite Parking:
0
# of Proposed Offsite Parking:
0
Offsite Parking Location:
Not Applicable
# of Proposed Accessible Parking:
0
# of Existing Bicycle Parking Spots:
0
# of Proposed Bicycle Parking Spots:
0
Tenant Relocation Assistance
Residential Unit Occupancy:
No Residential Units on Property
WASTE DIVERSION
Waste Diversion Plan Required:
No
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
No
Sprinklers Meet NFPA 13R:
No
Partial Fire Protection System:
No
Fire Alarm:
Yes
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Is any portion of the building semi-heated or unheated?:
Yes
Compliance Category:
Residential
Compliance Path:
Prescriptive
Is there a commercial kitchen hood exhaust system?:
No
Is there a fume hood?:
No
Is there a spray paint booth?:
No
Describe any other mechanical systems to be installed as part of this project.:
new heating system installed in existing shop and proposed art studio (type of heat to be determined)
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Residential:
Electric Heat Pump
DRAINAGE INFORMATION
Drainage Type of Work:
New
Number of Other New Drainage Connections:
1
Flow Control Type:
No Control
Flow Control Standard:
None
Treatment Standard Type:
No Treatment
Discharge Point:
Combined System
Total Disturbed Area:
2806
New Impervious Surface:
2176
New Plus Replaced Impervious Surface:
2176
Total Volume Managed by On-Site Stormwater Management (gallons):
10158
Total Area Requiring Soil Amendment:
630
SANITARY INFORMATION
Sanitary Type of Work:
Addition/Alteration
Number of New Connections to the Side Sewer:
1
Number of New Dwelling Units:
0
Reuse Existing Side Sewer System:
Yes
CONTRACTOR DISCLOSURE
Who will be performing all the work?:
Licensed Contractor
Contractor License:
PROFOCL934PN
CONTRACTOR DISCLOSURE
I have submitted an application for a building permit from the City of Seattle. I believe the work authorized by this permit is exempt from having a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work.:
No