PERMIT APPLICATION COMMON
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Multifamily
Project Value:
14468920
CONSTRUCTION VALUATION INFO
Intake Value: New:
13483295
Intake Value: Alteration:
0
Total Intake Value:
13483295
Issue Value: New:
15376984
Issue Value: Alteration:
0
Total Issued Value:
15376984
BUILDING CODE INFO
What building code was used for your design?:
2015 SBC
Action Type:
Add/Alt
Number of Proposed Building Stories:
5
Number of Proposed Below-Grade Building Stories:
0
Number of Mezzanines:
0
Is this a high-rise?:
No
Is a certificate of occupancy required?:
No
GROUND DISTURBANCE
Is the ground disturbance in an environmentally critical area?:
No
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
12/03/2019
Permit Issued Date:
09/09/2020
Inspections Completed Date:
05/05/2022
Certificate of Occupancy Issued Date:
05/05/2022
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
1
Curb Cut Size and Location:
Install and maintain one 20' wide curb cut along N 42nd St and beginning approx. 24' north of the south property line.
PARKING
Number of Proposed Onsite Parking Spaces:
59
Tenant Relocation Assistance
Residential Unit Occupancy:
No Units on Property
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
Sprinklers Meet NFPA 13R:
No
Partial Fire Protection System:
No
Fire Alarm:
Yes
Other Fire Protection System:
No
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
Yes
Elevator Pressurization:
Yes
Stairway Pressurization:
No
Smoke Removal System:
No
Accessible Elevator Egress:
Yes
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Is any portion of the building semi-heated or unheated?:
No
Compliance Category:
Residential
Compliance Path:
Total UA Alternative
Is there a commercial kitchen hood exhaust system?:
No
Is there a fume hood?:
No
Is there a spray paint booth?:
No
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Residential:
Unknown
Cooling Fuel Type Proposed: Residential:
Unknown
DRAINAGE INFORMATION
Drainage Type of Work:
New
Number of New Drainage Connections to the Main:
1
Flow Control Type:
No Control
Flow Control Standard:
None
Treatment Standard Type:
No Treatment
Discharge Point:
Storm System
Total Disturbed Area:
33715
New Impervious Surface:
0
New Plus Replaced Impervious Surface:
30366
Total Volume Managed by On-Site Stormwater Management (gallons):
25693
Total Area Requiring Soil Amendment:
2849
SANITARY INFORMATION
Sanitary Type of Work:
New
Number of New Sewer Connections to the Main:
0
Number of New Connections to the Side Sewer:
5
Number of Sewer New/Replaced/Repair Pumps:
0
Number of New Dwelling Units:
118
Reuse Existing Side Sewer System:
Yes