PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
01/15/2019
Permit Issued Date:
08/02/2019
Inspections Completed Date:
02/15/2022
Permit Remarks:
One 10' wide curb cut located along 39th @ 16.5' south of north property line. 2.5' flares allowed on either side.
CONSTRUCTION VALUATION INFO
Intake Value: New:
585947
Intake Value: Alteration:
0
Total Intake Value:
585947
Issue Value: New:
585947
Issue Value: Alteration:
0
Total Issued Value:
585947
PERMIT APPLICATION COMMON
Where on your property are you working?:
Proposed new residence would be over existing footprint extending to the west and slightly to the east.
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Single Family/Duplex
Project Value:
2400000
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
1
Curb Cut Size and Location:
One 10' wide curb cut located along 39th @ 16.5' south of north property line. 2.5' flares allowed on either side.
PARKING
# of Existing Onsite Parking:
0
# of Proposed Onsite Parking:
2
# of Proposed Offsite Parking:
0
Tenant Relocation Assistance
Residential Unit Occupancy:
Unit(s) Unoccupied
GROUND DISTURBANCE
Will your project have ground disturbance?:
Yes
Is your development site in an environmentally critical area (ECA)?:
Yes
Are you doing more than 2,000 square feet of earth disturbance?:
More than 1 cubic yard
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
Cut Depth in Feet (maximum):
12
Fill Depth in Feet (maximum):
6
Foundation Type:
Other
Does anyone live or work here?:
No
BUILDING CODE INFO
What building code was used for your design?:
2015 SBC (Struct) and SRC (Arch)
Is this a substantial alteration?:
No
Action Type:
New
Number of Existing Building Stories:
1.5
Number of Existing Below-Grade Building Stories:
1
Number of Proposed Building Stories:
1
Number of Proposed Below-Grade Building Stories:
1
Number of Mezzanines:
0
Is this a high-rise?:
No
Will you change the building use or occupancy?:
No
Main Existing Use of Building:
Residential
Existing Occupancy:
R-3 Single Family Dwelling
WASTE DIVERSION
Waste Diversion Plan Required:
Yes
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
No
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Is any portion of the building semi-heated or unheated?:
Yes
Compliance Category:
Residential
Compliance Path:
Prescriptive
Is there a fume hood?:
No
Is there a spray paint booth?:
No
Describe any other mechanical systems to be installed as part of this project.:
TBD
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Residential:
Unknown
Special Requirements:
solar ready
DRAINAGE INFORMATION
Drainage Type of Work:
New
Number of Other New Drainage Connections:
1
Flow Control Type:
No Control
Flow Control Standard:
None
Treatment Standard Type:
No Treatment
Discharge Point:
Combined System
Total Disturbed Area:
7808
New Impervious Surface:
1835
New Plus Replaced Impervious Surface:
3532
Total Volume Managed by On-Site Stormwater Management (gallons):
24494
Total Area Requiring Soil Amendment:
4109
SANITARY INFORMATION
Sanitary Type of Work:
New
Number of New Connections to the Side Sewer:
1
Number of New Dwelling Units:
1
Reuse Existing Side Sewer System:
Yes