PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
01/17/2019
Permit Issued Date:
07/31/2019
Inspections Completed Date:
02/18/2020
Certificate of Occupancy Issued Date:
02/18/2020
Permit Remarks:
15-foot curbcut located approximately 30-feet west of the NE property corner.
CONSTRUCTION VALUATION INFO
Intake Value: New:
429700
Intake Value: Alteration:
0
Total Intake Value:
429700
Issue Value: New:
429700
Issue Value: Alteration:
0
Total Issued Value:
429700
PERMIT APPLICATION COMMON
Where on your property are you working?:
The Building
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Commercial
Project Value:
250000
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
1
Curb Cut Size and Location:
15-foot curbcut located approximately 30-feet west of the NE property corner.
Tenant Relocation Assistance
Residential Unit Occupancy:
Unit(s) Unoccupied
GROUND DISTURBANCE
Will your project have ground disturbance?:
Yes
Is your development site in an environmentally critical area (ECA)?:
No
Are you doing more than 2,000 square feet of earth disturbance?:
More than 750 square feet
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
Cut Depth in Feet (maximum):
1.5
Fill Depth in Feet (maximum):
1.5
Foundation Type:
Other
Does anyone live or work here?:
No
BUILDING CODE INFO
What building code was used for your design?:
2015 SBC
Action Type:
New
Number of Proposed Building Stories:
1
Number of Proposed Below-Grade Building Stories:
0
Number of Mezzanines:
1
Is this a high-rise?:
No
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
Sprinklers Meet NFPA 13R:
No
Partial Fire Protection System:
No
Fire Alarm:
Yes
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
No
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Compliance Category:
Commercial
Compliance Path:
Component Performance
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Non-Residential:
Unknown
Special Requirements:
C406.2 (excuses C411) & C406.9/A1.4 and C412 ok/A2.1
SIDE SEWER INFORMATION
Related New Construction Project:
6694716
DRAINAGE INFORMATION
Number of Service Drain Lines Capped:
0
Drainage Type of Work:
New
Number of New Drainage Connections to the Main:
1
Number of Other New Drainage Connections:
0
Number of Drainage New/Replaced/Repair Pumps:
0
Flow Control Type:
No Control
Flow Control Standard:
Peak
Treatment Standard Type:
No Treatment
Discharge Point:
Storm System
Total Disturbed Area:
4995
New Impervious Surface:
3711
New Plus Replaced Impervious Surface:
4774
Total Volume Managed by On-Site Stormwater Management (gallons):
17272
Total Area Requiring Soil Amendment:
221
SANITARY INFORMATION
Number of Service Sewer Lines Capped:
1
Sanitary Type of Work:
New
Number of New Sewer Connections to the Main:
1
Number of New Connections to the Side Sewer:
0
Number of Sewer New/Replaced/Repair Pumps:
0
Number of New Dwelling Units:
0
Reuse Existing Side Sewer System:
No