PERMIT APPLICATION COMMON
Where on your property are you working?:
3/19/18:A.M.:CHANGED ADDRESS FROM 2707 S FERDINAND ST TO 2709 S FERDINAND ST
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Single Family/Duplex
Project Value:
500264
PERMIT TRACKING COMMON
Review Level:
Full +
Application Completed Date:
03/21/2018
Permit Issued Date:
10/17/2019
Permit Remarks:
Proposing to use an alley access located on south of property.
TPA sign and protection fencing required on northwest corner. Please see sheets CSC/Soil plan and A1.0 for more information.
CONSTRUCTION VALUATION INFO
Intake Value: New:
500264
Intake Value: Alteration:
0
Total Intake Value:
500264
Issue Value: New:
500264
Issue Value: Alteration:
0
Total Issued Value:
500264
BUILDING CODE INFO
What building code was used for your design?:
2015 SRC
Is this a substantial alteration?:
No
Action Type:
New
Number of Proposed Building Stories:
3
Number of Proposed Below-Grade Building Stories:
0
Number of Mezzanines:
0
Will you change the building use or occupancy?:
Yes
Is a certificate of occupancy required?:
No
GROUND DISTURBANCE
Land Disturbing Activity:
Yes
Is your development site in an environmentally critical area (ECA)?:
No
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
0
Curb Cut Size and Location:
Proposing to use an alley access located on south of property.
PARKING
# of Existing Accessible Parking:
2
# of Proposed Onsite Parking:
2
Tenant Relocation Assistance
Residential Unit Occupancy:
Unit(s) on Property Not Affected by Scope
WASTE DIVERSION
Waste Diversion Plan Required:
Yes
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Compliance Category:
Residential
Compliance Path:
Prescriptive
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Residential:
Natural Gas
DRAINAGE INFORMATION
Drainage Type of Work:
New
Number of Other New Drainage Connections:
1
Flow Control Type:
No Control
Flow Control Standard:
None
Treatment Standard Type:
No Treatment
Discharge Point:
Weep Hole
Total Disturbed Area:
5000
New Impervious Surface:
0
New Plus Replaced Impervious Surface:
2819
Total Volume Managed by On-Site Stormwater Management (gallons):
28635
Total Area Requiring Soil Amendment:
2043
SANITARY INFORMATION
Sanitary Type of Work:
New
Number of New Sewer Connections to the Main:
1
Number of New Dwelling Units:
1
Reuse Existing Side Sewer System:
No