PERMIT APPLICATION COMMON
Where on your property are you working?:
CHANGED ADDRESS FROM 730 TO 728 24TH AVE S
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Single Family/Duplex
Project Value:
250504
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
08/08/2017
Permit Issued Date:
08/21/2018
Inspections Completed Date:
07/26/2019
CONSTRUCTION VALUATION INFO
Intake Value: New:
250504
Intake Value: Alteration:
0
Total Intake Value:
250504
Issue Value: New:
250504
Issue Value: Alteration:
0
Total Issued Value:
250504
BUILDING CODE INFO
What building code was used for your design?:
2015 SRC
Is this a substantial alteration?:
No
Action Type:
New
Number of Proposed Building Stories:
3
Number of Proposed Below-Grade Building Stories:
0
Number of Mezzanines:
0
Will you change the building use or occupancy?:
Yes
Is a certificate of occupancy required?:
No
GROUND DISTURBANCE
Land Disturbing Activity:
Yes
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
1
Curb Cut Size and Location:
One curb cut, 10 feet wide located along east side of 24th Ave S, approximately 5 feet from the south property line. Separate SDOT Permit is required.
Tenant Relocation Assistance
Residential Unit Occupancy:
Unit(s) on Property Not Affected by Scope
WASTE DIVERSION
Waste Diversion Plan Required:
Yes
FIRE PROTECTION SYSTEMS
Other Fire Protection System:
Yes
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
No
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Compliance Category:
Residential
Compliance Path:
Prescriptive
ENERGY EQUIPMENT
AFUE Efficiency (percentage):
0
HSPF Efficiency (percentage):
0
Heating Fuel Type Proposed: Residential:
Electric Heat Pump
Special Requirements:
SEC 2015 EC - 1A, 3D, 5A, 5C
SIDE SEWER INFORMATION
Pipe Lining in the Right-of-Way:
No
Curb Crossing and/or Staging:
No
Excavation:
No
Roadway Restoration:
No
DRAINAGE INFORMATION
Number of Service Drain Lines Capped:
0
Drainage Type of Work:
New
Number of New Drainage Connections to the Main:
0
Number of Other New Drainage Connections:
1
Number of Drainage New/Replaced/Repair Pumps:
0
Flow Control Type:
No Control
Treatment Standard Type:
No Treatment
Discharge Point:
Other
Discharge Point Other Type:
"FORMERLY COMBINED"
Total Disturbed Area:
4876
New Impervious Surface:
1502
New Plus Replaced Impervious Surface:
3502
Total Volume Managed by On-Site Stormwater Management (gallons):
48025
Total Area Requiring Soil Amendment:
1374
SANITARY INFORMATION
Number of Service Sewer Lines Capped:
0
Sanitary Type of Work:
New
Number of New Sewer Connections to the Main:
0
Number of New Connections to the Side Sewer:
1
Number of Sewer New/Replaced/Repair Pumps:
0
Reuse Existing Side Sewer System:
Yes