PERMIT APPLICATION COMMON
Where on your property are you working?:
5-UNIT SOUTH BLDG - CHANGED ADDRESS FROM 6911 TO 6917 42ND AVE S 10/3/17 JH///CHANGED ADDRESS FROM 6929 TO 6911 42ND AVE S 10/3/17 JH (5-UNIT SOUTH BLDG)
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Single Family/Duplex
Project Value:
1156209
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
10/06/2017
Permit Issued Date:
04/29/2020
Inspections Completed Date:
05/08/2026
CONSTRUCTION VALUATION INFO
Intake Value: New:
1156209
Intake Value: Alteration:
0
Total Intake Value:
1156209
Issue Value: New:
1307422
Issue Value: Alteration:
0
Total Issued Value:
1307422
BUILDING CODE INFO
What building code was used for your design?:
2015 SRC
Is this a substantial alteration?:
No
Action Type:
New
Number of Proposed Building Stories:
3
Number of Proposed Below-Grade Building Stories:
0
Number of Mezzanines:
0
Is this a high-rise?:
No
Will you change the building use or occupancy?:
Yes
Is a certificate of occupancy required?:
No
GROUND DISTURBANCE
Land Disturbing Activity:
Yes
Is your development site in an environmentally critical area (ECA)?:
No
Are you doing more than 2,000 square feet of earth disturbance?:
Yes
New and Replaced Hard Surface > 750 sq ft?:
Yes
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
0
PARKING
# of Existing Onsite Parking:
0
# of Existing Offsite Parking:
0
# of Proposed Onsite Parking:
8
Tenant Relocation Assistance
Residential Unit Occupancy:
Unit(s) on Property Not Affected by Scope
WASTE DIVERSION
Waste Diversion Plan Required:
Yes
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Compliance Category:
Residential
Compliance Path:
Prescriptive
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Residential:
Electric Heat Pump
SIDE SEWER INFORMATION
Related New Construction Project:
6520217
Temporary Dewatering for Construction:
No
DRAINAGE INFORMATION
Drainage Type of Work:
New
Number of New Drainage Connections to the Main:
1
Flow Control Type:
No Control
Flow Control Standard:
None
Treatment Standard Type:
Basic
Discharge Point:
Storm System
Total Disturbed Area:
10710
New Impervious Surface:
6735
New Plus Replaced Impervious Surface:
8678
Total Volume Managed by On-Site Stormwater Management (gallons):
120363
Total Area Requiring Soil Amendment:
2032
SANITARY INFORMATION
Sanitary Type of Work:
New
Number of New Connections to the Side Sewer:
1
Number of New Dwelling Units:
8
Reuse Existing Side Sewer System:
Yes