PERMIT APPLICATION COMMON
Where on your property are you working?:
2/12/16 SAC - ADDRESS CHNGD FRM 1347 14TH AVE S TO 1322 S ATLANTIC STREET - ALL RESIDENTIAL UNITS FACE S ATLANTIC ST
Choose the Primary Property Use:
Multifamily
Project Value:
724399
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
02/03/2016
Permit Issued Date:
06/28/2016
Inspections Completed Date:
08/09/2017
Permit Remarks:
Priority Green Expedited; Two curb cuts, 10 feet wide located along north side of S. Atlantic St, approximately 25 feet from the east property line and 2nd curb cut apprx 33 feet from 1st curb cut. Separate SDOT Permit is required.
CONSTRUCTION VALUATION INFO
Intake Value: New:
724399
Intake Value: Alteration:
0
Total Intake Value:
724399
Issue Value: New:
724248
Issue Value: Alteration:
0
Total Issued Value:
724248
BUILDING CODE INFO
What building code was used for your design?:
2012 SRC
Specific Building Code:
2012 SRC
Is this a substantial alteration?:
No
Action Type:
New
Number of Proposed Building Stories:
3
Number of Proposed Below-Grade Building Stories:
0
Number of Mezzanines:
0
Will you change the building use or occupancy?:
Yes
Does your project qualify for our Priority Green Incentive program?:
Expedited
Is a certificate of occupancy required?:
No
GROUND DISTURBANCE
Land Disturbing Activity:
Yes
Are you doing more than 2,000 square feet of earth disturbance?:
Yes
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
2
Tenant Relocation Assistance
Residential Unit Occupancy:
Unit(s) on Property Not Affected by Scope
WASTE DIVERSION
Waste Diversion Plan Required:
Yes
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
No
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Compliance Category:
Residential
Compliance Path:
Prescriptive
ENERGY EQUIPMENT
AFUE Efficiency (percentage):
0
HSPF Efficiency (percentage):
0
Heating Fuel Type Proposed: Residential:
Unknown
SIDE SEWER INFORMATION
Pipe Lining in the Right-of-Way:
No
Curb Crossing and/or Staging:
No
Excavation:
No
Roadway Restoration:
No
DRAINAGE INFORMATION
Number of Service Drain Lines Capped:
0
Drainage Type of Work:
New
Number of New Drainage Connections to the Main:
0
Number of Other New Drainage Connections:
1
Number of Drainage New/Replaced/Repair Pumps:
0
Flow Control Type:
No Control
Treatment Standard Type:
No Treatment
Discharge Point:
Weep Hole
Total Disturbed Area:
5061
New Impervious Surface:
1785
New Plus Replaced Impervious Surface:
3924
Total Volume Managed by On-Site Stormwater Management (gallons):
2723
Total Area Requiring Soil Amendment:
1137
SANITARY INFORMATION
Number of Service Sewer Lines Capped:
0
Sanitary Type of Work:
New
Number of New Sewer Connections to the Main:
0
Number of New Connections to the Side Sewer:
1
Number of Sewer New/Replaced/Repair Pumps:
0
Reuse Existing Side Sewer System:
Yes