HISTORICAL
Hansen APNO:
6603210
Hansen APKEY:
730307
PERMIT APPLICATION COMMON
Where on your property are you working?:
To construct and maintain two curbcuts. One 20' wide along 6th Avenue beginning approx. 42' from the westerly property line and one 14'3" approx. 30' southwesterly of the northeasterly property line.
Is work in the right-of-way (street or alley) required?:
Yes
Choose the Primary Property Use:
Commercial
Project Value:
73587462
CONSTRUCTION VALUATION INFO
Intake Value: New:
73587462
Intake Value: Alteration:
0
Total Intake Value:
73587462
Issue Value: New:
73587462
Issue Value: Alteration:
0
Total Issued Value:
73587462
BUILDING CODE INFO
What building code was used for your design?:
2015 SBC
Is this a substantial alteration?:
No
Action Type:
New
Number of Proposed Building Stories:
43
Number of Proposed Below-Grade Building Stories:
9
Number of Mezzanines:
0
Is this a high-rise?:
Yes
Will you change the building use or occupancy?:
No
Is a certificate of occupancy required?:
Yes
GROUND DISTURBANCE
Land Disturbing Activity:
Yes
Is the ground disturbance in an environmentally critical area?:
Yes
What is the amount of ground disturbance?:
Yes
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
12/28/2017
Permit Issued Date:
11/06/2018
Inspections Completed Date:
08/17/2021
Certificate of Occupancy Issued Date:
08/17/2021
Permit Remarks:
PASV will be conducted under 3015251.
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
2
Curb Cut Size and Location:
To construct and maintain two curbcuts. One 20' wide along 6th Avenue beginning approx. 42' from the westerly property line and one 14'3" approx. 30' southwesterly of the northeasterly property line.
PARKING
Number of Proposed Onsite Parking Spaces:
266
Tenant Relocation Assistance
Residential Unit Occupancy:
Unit(s) on Property Not Affected by Scope
WASTE DIVERSION
Waste Diversion Plan Required:
No
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
Yes
Elevator Pressurization:
Yes
Exit and Pathway Lighting:
Yes
Stairway Pressurization:
Yes
Smoke Removal System:
Yes
Emergency Generator:
Yes
Accessible Elevator Egress:
Yes
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
Yes
Mechanical System Scope:
Phase 3
ENERGY CODE
Is any portion of the building semi-heated or unheated?:
Yes
Compliance Category:
Residential
Compliance Path:
Total Building Performance (TBP)
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Residential:
Other
Cooling Fuel Type Proposed: Residential:
Other
Heating Fuel Type Proposed: Non-Residential:
Other
Cooling Fuel Type Proposed: Non-Residential:
Other
Special Requirements:
C407.3 item 3 ( max. 93%) included onsite renewable C411 and heat recovery for service water heating C403.5.4. Proposed 90%
SIDE SEWER INFORMATION
Temporary Dewatering for Construction:
No
DRAINAGE INFORMATION
Number of Service Drain Lines Capped:
0
Drainage Type of Work:
New
Number of New Drainage Connections to the Main:
1
Number of Other New Drainage Connections:
0
Number of Drainage New/Replaced/Repair Pumps:
0
Flow Control Type:
Vault
Flow Control Standard:
Peak
Treatment Standard Type:
No Treatment
Discharge Point:
Combined System
Total Disturbed Area:
10665
New Impervious Surface:
0
New Plus Replaced Impervious Surface:
10665
Total Volume Managed by On-Site Stormwater Management (gallons):
42268
Total Area Requiring Soil Amendment:
0
SANITARY INFORMATION
Number of Service Sewer Lines Capped:
0
Sanitary Type of Work:
New
Number of New Sewer Connections to the Main:
2
Number of New Connections to the Side Sewer:
0
Number of Sewer New/Replaced/Repair Pumps:
0
Number of New Dwelling Units:
370
Reuse Existing Side Sewer System:
No