PERMIT APPLICATION COMMON
Choose the Primary Property Use:
Commercial
Project Value:
20953380
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
07/02/2015
Permit Issued Date:
05/12/2016
Inspections Completed Date:
03/29/2018
Certificate of Occupancy Issued Date:
03/29/2018
Permit Remarks:
To construct and maintain one 30' wide curbcut along Railroad Way S beginning approximately 7' south of the northerly property line.
CONSTRUCTION VALUATION INFO
Intake Value: New:
0
Intake Value: Alteration:
20953380
Total Intake Value:
20953380
Issue Value: New:
16622598
Issue Value: Alteration:
5964037
Total Issued Value:
22586635
BUILDING CODE INFO
What building code was used for your design?:
2012 SEBC Prescriptive
Specific Building Code:
2012 SEBC Prescriptive
Is this a substantial alteration?:
Yes
Action Type:
Add/Alt
Number of Existing Building Stories:
12
Number of Existing Below-Grade Building Stories:
0
Number of Proposed Building Stories:
12
Number of Proposed Below-Grade Building Stories:
0
Number of Mezzanines:
2
Is this a high-rise?:
Yes
Will you change the building use or occupancy?:
No
Does your project qualify for our Priority Green Incentive program?:
No
Is a certificate of occupancy required?:
Yes
GROUND DISTURBANCE
Land Disturbing Activity:
No
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
1
Tenant Relocation Assistance
Residential Unit Occupancy:
Unit(s) on Property Not Affected by Scope
WASTE DIVERSION
Waste Diversion Plan Required:
Yes
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
Yes
Elevator Pressurization:
Yes
Stairway Pressurization:
Yes
Accessible Elevator Egress:
Yes
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
Yes
ENERGY CODE
Compliance Category:
Commercial
Compliance Path:
Annual Energy Analysis
ENERGY EQUIPMENT
AFUE Efficiency (percentage):
0
HSPF Efficiency (percentage):
0
Heating Fuel Type Proposed: Non-Residential:
Electric Heat Pump
Special Requirements:
SEC C410: PV, heating & cooling loads calculation had been submitted for heat pump sizing
SANITARY INFORMATION
Reuse Existing Side Sewer System:
No