PERMIT APPLICATION COMMON
Where on your property are you working?:
2/27/2012 SLB CHANGED ADDRESS FROM 3438 TO 3438A 23RD AVE W (BLDG 2-WEST)
Choose the Primary Property Use:
Multifamily
Project Value:
387457
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
03/06/2012
Permit Issued Date:
07/05/2012
Inspections Completed Date:
03/19/2013
Permit Remarks:
Grading Limited to Apr 1 to Oct 31, unless DPD provides grading season extension letter. All cuts/fills must be stabilized by Oct 31st.
CONSTRUCTION VALUATION INFO
Intake Value: New:
387457
Intake Value: Alteration:
0
Total Intake Value:
387457
Issue Value: New:
378960
Issue Value: Alteration:
0
Total Issued Value:
378960
BUILDING CODE INFO
What building code was used for your design?:
2009 SRC
Specific Building Code:
2009 SRC
Action Type:
New
Number of Proposed Building Stories:
3
Number of Proposed Below-Grade Building Stories:
1
Number of Mezzanines:
0
Will you change the building use or occupancy?:
Yes
Does your project qualify for our Priority Green Incentive program?:
No
Is a certificate of occupancy required?:
No
GROUND DISTURBANCE
Land Disturbing Activity:
Yes
Are you doing more than 2,000 square feet of earth disturbance?:
Yes
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
1
Tenant Relocation Assistance
Residential Unit Occupancy:
Unit(s) on Property Not Affected by Scope
WASTE DIVERSION
Waste Diversion Plan Required:
No
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
No
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Compliance Category:
Residential
Compliance Path:
Prescriptive
ENERGY EQUIPMENT
AFUE Efficiency (percentage):
0
HSPF Efficiency (percentage):
0
SIDE SEWER INFORMATION
Pipe Lining in the Right-of-Way:
No
Curb Crossing and/or Staging:
No
Excavation:
No
Roadway Restoration:
No
DRAINAGE INFORMATION
Number of Service Drain Lines Capped:
0
Drainage Type of Work:
New
Number of New Drainage Connections to the Main:
0
Number of Other New Drainage Connections:
1
Number of Drainage New/Replaced/Repair Pumps:
0
Flow Control Type:
No Control
Treatment Standard Type:
No Treatment
Discharge Point:
Combined System
Total Disturbed Area:
5990
New Impervious Surface:
3798
New Plus Replaced Impervious Surface:
3798
Total Volume Managed by On-Site Stormwater Management (gallons):
1280
Total Area Requiring Soil Amendment:
2200
SANITARY INFORMATION
Number of Service Sewer Lines Capped:
0
Sanitary Type of Work:
New
Number of New Sewer Connections to the Main:
1
Number of New Connections to the Side Sewer:
0
Number of Sewer New/Replaced/Repair Pumps:
0
Reuse Existing Side Sewer System:
No