PERMIT APPLICATION COMMON
Choose the Primary Property Use:
Commercial
Project Value:
585477
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
11/30/2011
Permit Remarks:
Two construct two two way curbcuts, one 25' wide two way curbcut to be located along 30th Avenue NE approximately 75' south of the north property line and one 30' wide two way curbcut located along Lake City Way NE approximately 116' north of the south property line. All existing unused curbcuts to be replaced with curb, sidewalk, landscaping ect, per SDOT standards.
CONSTRUCTION VALUATION INFO
Intake Value: New:
585477
Intake Value: Alteration:
0
Total Intake Value:
585477
Issue Value: New:
585477
Issue Value: Alteration:
0
Total Issued Value:
585477
BUILDING CODE INFO
Action Type:
New
Number of Proposed Building Stories:
1
Number of Proposed Below-Grade Building Stories:
0
Number of Mezzanines:
0
Is this a high-rise?:
No
Will you change the building use or occupancy?:
Yes
Is a certificate of occupancy required?:
Yes
GROUND DISTURBANCE
Land Disturbing Activity:
Yes
Are you doing more than 2,000 square feet of earth disturbance?:
Yes
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
2
Tenant Relocation Assistance
Residential Unit Occupancy:
Residential Units on Property Not Affected by Scope
WASTE DIVERSION
Waste Diversion Plan Required:
No
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
No
Elevator Pressurization:
No
Stairway Pressurization:
No
Accessible Elevator Egress:
No
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
Yes
SIDE SEWER INFORMATION
Pipe Lining in the Right-of-Way:
No
Curb Crossing and/or Staging:
No
Excavation:
No
Roadway Restoration:
No
DRAINAGE INFORMATION
Number of Service Drain Lines Capped:
0
Drainage Type of Work:
New
Number of New Drainage Connections to the Main:
0
Number of Other New Drainage Connections:
1
Number of Drainage New/Replaced/Repair Pumps:
0
Flow Control Type:
Infiltration
Flow Control Standard:
Pasture
Treatment Standard Type:
Basic
Discharge Point:
On Site
Total Disturbed Area:
26653
New Impervious Surface:
18105
New Plus Replaced Impervious Surface:
18105
Total Volume Managed by On-Site Stormwater Management (gallons):
560
Total Area Requiring Soil Amendment:
7000
SANITARY INFORMATION
Number of Service Sewer Lines Capped:
0
Sanitary Type of Work:
New
Number of New Sewer Connections to the Main:
0
Number of New Connections to the Side Sewer:
1
Number of Sewer New/Replaced/Repair Pumps:
0
Reuse Existing Side Sewer System:
Yes