Skip Module Navigation
 

Message Bar

Search All Records

Record Number: 6878350-CN

Construction Permit

Record Status: Corrections Required

 
   
Add
 
 
 

Work Location

 
 

Record Details

ExpandMore Details

 

Expand Application Information

PERMIT APPLICATION COMMON
Where on your property are you working?:
The entire site.
Is work in the right-of-way (street or alley) required?:
Yes
Choose the Primary Property Use:
Multifamily
Project Value:
46000000
 
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
03/06/2024
 
FLOATING RESIDENCE INFO
Is this building a Floating Residence?:
No
 
CONSTRUCTION VALUATION INFO
Intake Value: New:
34785039
Intake Value: Alteration:
0
Total Intake Value:
34785039
Issue Value: New:
34785039
Issue Value: Alteration:
0
Total Issued Value:
34785039
 
INTERDEPARTMENTAL COORDINATION
SDOT Concept Approval:
Yes
SDOT Permit Accepted:
Yes
SDOT SIP PM:
MST
 
BUILDING CODE INFO
What building code was used for your design?:
2018 SBC
Is this a substantial alteration?:
No
Are you changing the envelope?:
No
Action Type:
New
Number of Existing Building Stories:
4
Number of Existing Below-Grade Building Stories:
0
Number of Proposed Building Stories:
10
Number of Proposed Below-Grade Building Stories:
3
Number of Mezzanines:
0
Is this a high-rise?:
No
Will you change the building use or occupancy?:
Yes
Main Existing Use of Building:
Business
Existing Occupancy:
B Restaurant < 50 Occupants
Will your application include a new standard plan?:
No
Is a certificate of occupancy required?:
Yes
 
GROUND DISTURBANCE
Is your development site in an environmentally critical area (ECA)?:
Yes
New and Replaced Hard Surface > 750 sq ft?:
Yes
Are you doing more than 2,000 square feet of earth disturbance?:
Yes
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
Foundation Type:
Spread Footing
 
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
1
Curb Cut Size and Location:
Approximately 26-feet wide in SW corner of site.
 
PARKING
# of Existing Onsite Parking:
0
# of Existing Offsite Parking:
0
# of Existing Accessible Parking:
0
# of Proposed Onsite Parking:
111
# of Proposed Offsite Parking:
0
# of Proposed Accessible Parking:
4
# of Existing Bicycle Parking Spots:
0
# of Proposed Bicycle Parking Spots:
148
 
Tenant Relocation Assistance
Residential Unit Occupancy:
No Residential Units on Property
 
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
Sprinklers Meet NFPA 13R:
No
Partial Fire Protection System:
No
Fire Alarm:
Yes
Other Fire Protection System:
No
 
EMERGENCY SYSTEMS
Are Emergency Systems Required for this Project?:
Yes
Elevator Pressurization:
No
Stairway Pressurization:
Yes
Smoke Removal System:
No
Accessible Elevator Egress:
Yes
 
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
Yes
 
MECHANICAL DUCTWORK LOCATION
Is there any equipment inside?:
Yes
Is there any rooftop equipment? :
Yes
 
ENERGY CODE
Is any portion of the building semi-heated or unheated?:
Yes
Compliance Category:
Commercial
Compliance Path:
Total Building Performance (TBP)
Is there a commercial kitchen hood exhaust system?:
Yes
Is there a fume hood?:
No
Is there a spray paint booth?:
No
 
ENERGY EQUIPMENT
Heating Fuel Type Proposed: Residential:
Electric Resistance
Heating Fuel Type Proposed: Non-Residential:
Electric Heat Pump
Special Requirements:
elec.resistance heat for units using exception of C403.1.4.. HP water heater schedules on P0.03. no onsite renewable, no C406, Lighting savings claimed in C407 report.
 
DRAINAGE INFORMATION
Number of Service Drain Lines Capped:
1
Drainage Type of Work:
New
Number of New Drainage Connections to the Main:
1
Flow Control Type:
No Control
Flow Control Standard:
None
Treatment Standard Type:
No Treatment
Discharge Point:
Storm System
Total Disturbed Area:
25927
New Impervious Surface:
0
New Plus Replaced Impervious Surface:
25561
Total Volume Managed by On-Site Stormwater Management (gallons):
146648
Total Area Requiring Soil Amendment:
366
 
SANITARY INFORMATION
Sanitary Type of Work:
New
Number of New Sewer Connections to the Main:
1
Number of New Connections to the Side Sewer:
1
Number of New Dwelling Units:
178
Reuse Existing Side Sewer System:
Yes
 
SPECIAL PROGRAMS
Is this project receiving Opportunity Zone Funds?:
No
 
CONTRACTOR DISCLOSURE
Who will be performing all the work?:
Licensed Contractor
Contractor License:
SIERRCC145N8

Expand Other Information

LAND USE PROPOSED
Use:
Vacant Land, no established use
Sq. Ft.:
0
Floor(s):
0
Use:
Vacant Land, no established use
Sq. Ft.:
0
Floor(s):
0
Use:
Vacant Land, no established use
Sq. Ft.:
0
Floor(s):
0
 
HOUSING UNITS
Type of Housing Unit:
Apartment
Number of Existing Units:
0
Number of Removed Units:
0
Number of Added Units:
150
Number of Sleeping Rooms:
0
Type of Housing Unit:
Small Efficiency Dwelling
Number of Existing Units:
0
Number of Removed Units:
0
Number of Added Units:
28
Number of Sleeping Rooms:
0
 
BUILDING USE & OCCUPANCY
Floor or Area:
L1 - Lobby
Floor Area (square feet):
1120
Occupancy Group:
Other A-3 Occupancy
Type of Construction:
Type IA
Sprinkler Standard:
Full System
Floor or Area:
L1 - Theater
Floor Area (square feet):
805
Occupancy Group:
A-1 Theater
Type of Construction:
Type IA
Sprinkler Standard:
Full System
Floor or Area:
L8 - Roof Amenity
Floor Area (square feet):
2582
Occupancy Group:
Other A-3 Occupancy
Type of Construction:
Type IIIA
Sprinkler Standard:
None
Floor or Area:
L2 - Restaurant
Floor Area (square feet):
4303
Occupancy Group:
A-2 Restaurant
Type of Construction:
Type IA
Sprinkler Standard:
Full System
Floor or Area:
L1,2 - Res Amenities
Floor Area (square feet):
2830
Occupancy Group:
Other B Occupancy
Type of Construction:
Type IA
Sprinkler Standard:
Full System
Floor or Area:
L1 - Outdoor Amenities
Floor Area (square feet):
543
Occupancy Group:
Other B Occupancy
Type of Construction:
None
Sprinkler Standard:
None
Floor or Area:
P1 - Retail
Floor Area (square feet):
1431
Occupancy Group:
M Retail
Type of Construction:
Type IA
Sprinkler Standard:
Full System
Floor or Area:
L1,2 - Residential
Floor Area (square feet):
11982
Occupancy Group:
R-2 Apartment/Condominium
Type of Construction:
Type IA
Sprinkler Standard:
Full System
Floor or Area:
L3-8 - Residential
Floor Area (square feet):
97854
Occupancy Group:
R-2 Apartment/Condominium
Type of Construction:
Type IIIA
Sprinkler Standard:
Full System
Floor or Area:
L1,P1,P2 - Garage
Floor Area (square feet):
38651
Occupancy Group:
S-2 Parking Garage - Enclosed
Type of Construction:
Type IA
Sprinkler Standard:
Full System
Floor or Area:
L1,P1,P2 - Storage
Floor Area (square feet):
7476
Occupancy Group:
S-1 Storage - Moderate Hazard
Type of Construction:
Type IA
Sprinkler Standard:
Full System
 
REQUIRED DOCUMENTS
Must this be recorded?:
No
Must this be recorded?:
No
Must this be recorded?:
No
Must this be recorded?:
No
Must this be recorded?:
No
Must this be recorded?:
Yes
Recording Number:
20240813000121
Date Received for Recording:
08/13/2024
Must this be recorded?:
Yes
Recording Number:
20241025000460
 
KEY INSPECTION ISSUES
Reviewer:
Branin Burdette
Review:
Zoning
Key Inspection Issue:
Landscape Improvement Checklist
Key Issue Description:
Verify landscaping is installed per approved plans.
Date Added:
08/16/2024
 
FENESTRATION
Occupancy Group:
Multifamily Residential
Fenestration Type:
Vertical Glazing
U Max:
0.26
SHGC Max:
0.22
Comments:
vinyl
Occupancy Group:
Multifamily Residential
Fenestration Type:
Vertical Glazing
U Max:
0.26
SHGC Max:
0.22
Comments:
sliding door
Occupancy Group:
Multifamily Residential
Fenestration Type:
Vertical Glazing
U Max:
0.38
SHGC Max:
0.38
Comments:
storefront
Occupancy Group:
Multifamily Residential
Fenestration Type:
Opaque Door
U Max:
0.37
 
OPAQUE ELEMENTS
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Floor: Mass
Cavity R-Value:
38
Comments:
F4
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Floor Over Unconditioned Space
Cont R-Value:
39
Comments:
F5
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Roof or Ceiling Single Rafter
Cont R-Value:
39
Comments:
Avg. R1
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Roof or Ceiling Single Rafter
Cavity R-Value:
21
Comments:
R3
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Wall: Above Grade Wood Framing
Cavity R-Value:
21
Comments:
E1, E4.1, E5
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Wall: Above Grade Wood Framing
Cavity R-Value:
25
Comments:
E2, E2.1
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Wall: Above Grade Steel Framing
Cavity R-Value:
21
Comments:
B2.1, B4
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Wall: Above Grade Mass
Cavity R-Value:
19
Comments:
metal frame B6 +C1
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Wall: Above Grade Mass
Cavity R-Value:
21
Comments:
B2.1+C1, B4+c1
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Wall: Above Grade Mass
Cont R-Value:
12.5
Comments:
B9+C1
Occupancy Group:
Multifamily Residential
Insulation Assembly:
Wall: Above Grade Mass
Cavity R-Value:
0
Cont R-Value:
0
Comments:
C1
 
RESIDENTIAL ENERGY EQUIP SIZES
Unit ID:
101
Allowance Factor:
1.25
Minimum BTUs:
5350
Unit ID:
103
Minimum BTUs:
2900
Unit ID:
105
Minimum BTUs:
3510
Unit ID:
107
Minimum BTUs:
4000
Unit ID:
111
Minimum BTUs:
1940
Unit ID:
113
Minimum BTUs:
2860
Unit ID:
115
Minimum BTUs:
2860
Unit ID:
117
Minimum BTUs:
2650
Unit ID:
122
Minimum BTUs:
3930
Unit ID:
123
Minimum BTUs:
3550
Unit ID:
125
Minimum BTUs:
2900
Unit ID:
127
Minimum BTUs:
2900
Unit ID:
129
Minimum BTUs:
3100
Unit ID:
201
Minimum BTUs:
5350
Unit ID:
203
Minimum BTUs:
2670
Unit ID:
205
Minimum BTUs:
2670
Unit ID:
207
Minimum BTUs:
4000
Unit ID:
211
Minimum BTUs:
1940
Unit ID:
213
Minimum BTUs:
2630
Unit ID:
215
Minimum BTUs:
2630
Unit ID:
217
Minimum BTUs:
2250
Unit ID:
219
Minimum BTUs:
9950
Unit ID:
221
Minimum BTUs:
3040
Unit ID:
223
Minimum BTUs:
3040
Unit ID:
225
Minimum BTUs:
3040
Unit ID:
226
Minimum BTUs:
3020
Unit ID:
227
Minimum BTUs:
3040
Unit ID:
228
Minimum BTUs:
3020
Unit ID:
229
Minimum BTUs:
9940
Unit ID:
230
Minimum BTUs:
9940
Unit ID:
300-600
Minimum BTUs:
6940
Unit ID:
301-601
Minimum BTUs:
5350
Unit ID:
302-602
Minimum BTUs:
3020
Unit ID:
303-603
Minimum BTUs:
2670
Unit ID:
304-604
Minimum BTUs:
3020
Unit ID:
305-605
Minimum BTUs:
2670
Unit ID:
306-606
Minimum BTUs:
2900
Unit ID:
307-607
Minimum BTUs:
4000
Unit ID:
308-608
Minimum BTUs:
3020
Unit ID:
310-610
Minimum BTUs:
3020
Unit ID:
311-611
Minimum BTUs:
1940
Unit ID:
312-612
Minimum BTUs:
3020
Unit ID:
314-614
Minimum BTUs:
6990
Unit ID:
315-615
Minimum BTUs:
2620
Unit ID:
316-616
Minimum BTUs:
2250
Unit ID:
317-617
Minimum BTUs:
2250
Unit ID:
318-618
Minimum BTUs:
3020
Unit ID:
319-619
Minimum BTUs:
9950
Unit ID:
320-620
Minimum BTUs:
3020
Unit ID:
321-621
Minimum BTUs:
3040
Unit ID:
322-622
Minimum BTUs:
3020
Unit ID:
323-623
Minimum BTUs:
3040
Unit ID:
324-624
Minimum BTUs:
2900
Unit ID:
325-525
Minimum BTUs:
3040
Unit ID:
326-526
Minimum BTUs:
3020
Unit ID:
327-527
Minimum BTUs:
3040
Unit ID:
328-528
Minimum BTUs:
3020
Unit ID:
329-529
Minimum BTUs:
4390
Unit ID:
330-530
Minimum BTUs:
9160
Unit ID:
625
Minimum BTUs:
3790
Unit ID:
626
Minimum BTUs:
3130
Unit ID:
627
Minimum BTUs:
9100
Unit ID:
700
Minimum BTUs:
8200
Unit ID:
701
Minimum BTUs:
5920
Unit ID:
702
Minimum BTUs:
3130
Unit ID:
703
Minimum BTUs:
3570
Unit ID:
704
Minimum BTUs:
2900
Unit ID:
705
Minimum BTUs:
4000
Unit ID:
706
Minimum BTUs:
3130
Unit ID:
708
Minimum BTUs:
9570
Unit ID:
710
Minimum BTUs:
3830
Unit ID:
711
Minimum BTUs:
2230
Unit ID:
713
Minimum BTUs:
2910
Unit ID:
714
Minimum BTUs:
3470
Unit ID:
715
Minimum BTUs:
2910
Unit ID:
716
Minimum BTUs:
3470
Unit ID:
717
Minimum BTUs:
2530
Unit ID:
718
Minimum BTUs:
3240
Unit ID:
719
Minimum BTUs:
1190
Unit ID:
720
Minimum BTUs:
3470
Unit ID:
721
Minimum BTUs:
3470
Unit ID:
723
Minimum BTUs:
3470
Unit ID:
725
Minimum BTUs:
4220
Unit ID:
727
Minimum BTUs:
9970
Unit ID:
800
Minimum BTUs:
9120
Unit ID:
801
Minimum BTUs:
6670
Unit ID:
802
Minimum BTUs:
3470
Unit ID:
803
Minimum BTUs:
4090
Unit ID:
804
Minimum BTUs:
3240
Unit ID:
805
Minimum BTUs:
4820
Unit ID:
806
Minimum BTUs:
3470
Unit ID:
808
Minimum BTUs:
9210

Expand Parcel Information


Development Site Parcel:DV0351500 *
Block:--
Lot:--
Subdivision:--

 

Fees

You can find all fees assessed to date for your application or permit listed below.

For your outstanding fees:

  • To view or print a statement of fees due, select Reports in the upper right corner and select Fees Due Statement.
  • To make a credit card payment, select the Pay Fees link. For additional information, see How to Pay Fees.

For your paid fees:

  • To view or print your receipt, select the View Receipt link.
  • To view or print a report of all fees assessed and payments received to date, select Reports in the upper right corner and select Payment and Fee Detail.
Loading...
 

Inspections & Appointments

To view all inspections on this permit, click the Reports link in the upper right, next to the Login button. It displays all inspections submitted into our system by the end of the previous day.

Common Inspection Tips:

  • To schedule a Pre-Construction Conference or Grading Season meeting, please call (206) 684-8860 between 7:30 AM and 4:00 PM, Monday - Friday.
  • To schedule a Land Use/Design Review inspection, please email the assigned Land Use Planner at least one week before the desired inspection date. Their information is displayed on the construction permit face.
  • To find the inspector performing your inspection: Search for your Scheduled inspection below in "The Following Are Required:" You may have to click Next if there are multiple pages. Your assigned inspector's name will appear below the inspection type.
  • For Side Sewer permits, Sanitary Final and Drainage Final inspections cannot be scheduled online. Please schedule a Sanitary Cover or Drainage Cover for all side sewer inspection needs.
  • If you are having any other issues scheduling an inspection, please call our Inspection Scheduling Line at (206) 684-8950 between 7:30 AM and 4:00 PM, Monday - Friday.
  • For Developer Contribution Housing Inspections only, contact the Office of Housing.
Loading...

The Following Are Required:

 
There are no required inspections for this record number.
 
 

The Following Are Completed:

 
 

Attachments

Do not use this page for submitting materials unless instructed to do so by SDCI staff. To submit materials for permit application intake, addressing corrections, or responding to a SDCI request for more information, use the "Make Changes" button next to the respective record on the My Records page. This action ensures that your materials are promptly reviewed by SDCI staff.

To upload your document, you need to attach it to your application. After selecting your documents, choose a Type and add a Description for each document.

The maximum file size allowed is 1000 MB.
386;3gr;add;ade;adp;asp;bas;bat;cad;chm;cmd;com;com;cpl;crt;dbx;dif;dll;docm;dot;dotm;dotx;dwg;dxf;exe;fon;hlp;hta;htm;html;inf;ins;isp;jar;js;jse;lib;lnk;mdb;mde;mht;mhtml;msc;msi;msp;mst;ocx;odt;pcd;php;pif;ppt;pptm;pptx;prn;rar;reg;rtf;scr;sct;shb;shs;slk;sys;txt;url;vb;vb[usrv:es];vbe;vbs;vxd;wps;ws[usrv:cfh];wsc;wsf;wsh;xla;xlam;xlsb;xlsm;xlt;xml;zip are disallowed file types to upload.
Click the document name to start the download. Please avoid clicking twice. Larger files will take a few moments to begin.
 

Notes

Notes from SDCI (0 total, newest first):

 
Loading...
Loading...
 

Right Of Way Management