PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
02/04/2020
Permit Remarks:
Address changed from 815 Western Ave. slm 6/03/2021
CONSTRUCTION VALUATION INFO
Intake Value: New:
0
Intake Value: Alteration:
5500000
Total Intake Value:
5500000
Total Issued Value:
0
PERMIT APPLICATION COMMON
Where on your property are you working?:
entire site
Is work in the right-of-way (street or alley) required?:
Yes
Choose the Primary Property Use:
Commercial
Project Value:
5500000
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
2
Curb Cut Size and Location:
unknown at this time
PARKING
# of Existing Onsite Parking:
45
# of Existing Offsite Parking:
0
# of Existing Accessible Parking:
3
# of Proposed Onsite Parking:
225
# of Proposed Offsite Parking:
0
Offsite Parking Location:
n/a
# of Proposed Accessible Parking:
10
# of Existing Bicycle Parking Spots:
0
# of Proposed Bicycle Parking Spots:
75
Tenant Relocation Assistance
Residential Unit Occupancy:
No Residential Units on Property
GROUND DISTURBANCE
Will your project have ground disturbance?:
Yes
Is your development site in an environmentally critical area (ECA)?:
Yes
Are you doing more than 2,000 square feet of earth disturbance?:
More than 1 cubic yard
I, the owner or owner’s authorized representative of the property referenced in this submission, give the City of Seattle Department of Planning and Development permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector’s ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
Cut Depth in Feet (maximum):
30
Fill Depth in Feet (maximum):
0
Foundation Type:
Spread Footing
Does anyone live or work here?:
Yes
Is the disposal site inside the city?:
No
BUILDING CODE INFO
What building code was used for your design?:
2015 SBC
Is this a substantial alteration?:
No
Are you changing the envelope?:
No
Action Type:
New
Number of Existing Building Stories:
4
Number of Existing Below-Grade Building Stories:
0
Number of Proposed Building Stories:
18
Number of Proposed Below-Grade Building Stories:
3
Number of Mezzanines:
0
Is this a high-rise?:
Yes
Will you change the building use or occupancy?:
No
Main Existing Use of Building:
Business
Existing Occupancy:
B Office
Will your application include a new standard plan?:
No
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
Sprinklers Meet NFPA 13R:
Yes
Fire Alarm:
Yes
Other Fire Protection System:
Yes
MECHANICAL CODE
Does your project include an HVAC mechanical system?:
No
ENERGY CODE
Is any portion of the building semi-heated or unheated?:
Yes
Compliance Category:
Commercial
Compliance Path:
Target Performance Path (TPP)
Is there a commercial kitchen hood exhaust system?:
Yes
Is there a fume hood?:
Yes
Is there a spray paint booth?:
No
Describe any other mechanical systems to be installed as part of this project.:
unknown at this time