PROJECT TYPE
I'm constructing a new building:
Yes
I'm making additions or changes to an existing building:
No
I'm putting up a temporary structure (e.g., tent or booth):
No
I'm tearing down a building:
Yes
I'm installing or repairing a mechanical system:
No
I'm changing the use of a building (e.g., from office to retail space):
Yes
I need a master use permit:
Yes
I'm subdividing a property:
No
I'm changing a lot boundary:
No
I need a variance from the zoning code:
No
I'm installing a curb cut (ramp from sidewalk to street):
Yes
I'm doing grading or installing drainage:
Yes
I need a shoreline exemption to remove a hazardous tree:
No
I'm planning on using an existing approved standard plan set:
No
I think my project qualifies as subject-to-field-inspection or a DADU standard plan:
No
I am requesting a pre-submittal conference:
Yes
PERMIT APPLICATION COMMON
Where on your property are you working?:
The project will be the full block (which is triangular in shape)
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Multifamily
Project Value:
80000000
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
1
Curb Cut Size and Location:
Yale Ave, 24'
PARKING
Number of Existing Onsite Parking Spaces:
60
Number of Existing Offsite Parking Spaces:
0
Number of Existing Accessible Parking Spaces:
2
Number of Proposed Onsite Parking Spaces:
220
Number of Proposed Offsite Parking Spaces:
0
Offsite Parking Location:
NA
Number of Proposed Accessible Parking Spaces:
9
Number of Existing Bicycle Parking Spots:
0
Number of Proposed Bicycle Parking Spots:
340
GROUND DISTURBANCE
Will your project have ground disturbance?:
Yes
Is your development site in an environmentally critical area (ECA)?:
No
Cut Depth in Feet (maximum):
50
Fill Depth in Feet (maximum):
0
Foundation Type:
Basement
Does anyone live or work here?:
Yes
Is the disposal site inside the city?:
Yes
BUILDING CODE INFO
What building code was used for your design?:
2015 SBC (Struct) and SRC (Arch)
Is this a substantial alteration?:
No
Are you changing the envelope?:
Yes
Action Type:
New
Number of Existing Building Stories:
2
Number of Existing Below-Grade Building Stories:
0
Number of Proposed Building Stories:
45
Number of Proposed Below-Grade Building Stories:
4
Number of Mezzanines:
0
Is this a high-rise?:
Yes
Will you change the building use or occupancy?:
Yes
Main Existing Use of Building:
Business
Existing Occupancy:
B Office
Will your application include a new standard plan?:
No
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
Fire Alarm:
Yes
MECHANICAL LOCATION INFO
Is there any equipment inside?:
Yes
Is there any ground-mounted exterior equipment?:
No
Is there any wall-mounted exterior equipment?:
No
Is there any rooftop equipment?:
Yes
MECHANICAL APPLICATION INFO
Is there work on more than two adjacent floors?:
Yes
Are there fire dampers or stair/elevator pressurization fans or penetrations through TI (Tenant/Occupancy) separation walls or any rated assembly (such as a wall, floor, or ceiling)?:
Yes
Are there commercial kitchen hoods?:
No
Are there less than 4 units in the building?:
No
Are you altering or replacing an existing mechanical installation?:
Yes
Is this permit for initial tenant improvements?:
Yes
Are you installing new equipment?:
Yes
Is there a reference building permit?:
No
Do you have any equipment that is over 400 pounds?:
Yes
Is there any existing or new mechanical equipment?:
Yes
Are you providing computer system analysis for energy code compliance?:
No
ENERGY CODE
Portion of Building Semi-Heated or Unheated:
No
Compliance Category:
Commercial
Is there a commercial kitchen hood exhaust system?:
No
Is there a fume hood?:
No
Is there a spray paint booth?:
No
Describe Mechanical Systems Being Installed (if any):
TBD