PROJECT TYPE
I'm constructing a new building:
Yes
I'm making additions or changes to an existing building:
No
I'm putting up a temporary structure (e.g., tent or booth):
No
I'm tearing down a building:
Yes
I'm changing the use of a building (e.g., from office to retail space):
No
I need a master use permit:
No
I'm subdividing a property:
No
I'm changing a lot boundary:
No
I need a variance from the zoning code:
No
I'm installing a curb cut (ramp from sidewalk to street):
No
I'm doing grading or installing drainage:
No
I need a shoreline exemption to remove a hazardous tree:
No
I'm planning on using an existing approved standard plan set:
No
I think my project qualifies as subject-to-field-inspection or a DADU standard plan:
No
I am requesting a pre-submittal conference:
No
I have a vacant building on the record site address:
No
PERMIT APPLICATION COMMON
Where on your property are you working?:
Onsite
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Multifamily
Project Value:
75000000
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
0
Curb Cut Size and Location:
0
PARKING
Number of Existing Onsite Parking Spaces:
48
Number of Existing Offsite Parking Spaces:
0
Number of Existing Accessible Parking Spaces:
0
Number of Proposed Onsite Parking Spaces:
80
Number of Proposed Offsite Parking Spaces:
0
Offsite Parking Location:
0
Number of Proposed Accessible Parking Spaces:
0
Number of Existing Bicycle Parking Spots:
0
Number of Proposed Bicycle Parking Spots:
0
GROUND DISTURBANCE
Is your development site in an environmentally critical area (ECA)?:
No
New and Replaced Hard Surface > 750 sq ft?:
Yes
Are you doing more than 750 square feet of earth disturbance?:
Yes
I, the owner or owner's authorized representative of the property referenced in this submission, give the City of Seattle Department of Construction and Inspections permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector's ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
Yes
Foundation Type:
Spread Footing
BUILDING CODE INFO
What building code was used for your design?:
2018 SBC (Struct) and SRC (Arch)
Is this a substantial alteration?:
No
Are you changing the envelope?:
No
Action Type:
New
Number of Existing Building Stories:
5
Number of Existing Below-Grade Building Stories:
1
Number of Proposed Building Stories:
28
Number of Proposed Below-Grade Building Stories:
3
Number of Mezzanines:
0
Is this a high-rise?:
Yes
Will you change the building use or occupancy?:
No
Main Existing Use of Building:
Business
Existing Occupancy:
B Office
Will your application include a new standard plan?:
Yes
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
Sprinklers Meet NFPA 13R:
Yes
Partial Fire Protection System:
Yes
Fire Alarm:
Yes
ENERGY CODE
Portion of Building Semi-Heated or Unheated:
Yes
Compliance Category:
Residential
Is there a commercial kitchen hood exhaust system?:
No
Is there a fume hood?:
No
Is there a spray paint booth?:
No
SPECIAL PROGRAMS
Is this project receiving Opportunity Zone Funds?:
No