PROJECT TYPE
I'm constructing a new building:
Yes
I'm making additions or changes to an existing building:
No
I'm putting up a temporary structure (e.g., tent or booth):
No
I'm tearing down a building:
No
I'm changing the use of a building (e.g., from office to retail space):
No
I need a master use permit:
No
I'm subdividing a property:
No
I'm changing a lot boundary:
No
I need a variance from the zoning code:
No
I'm installing a curb cut (ramp from sidewalk to street):
No
I'm doing grading or installing drainage:
No
I need a shoreline exemption to remove a hazardous tree:
No
I'm planning on using an existing approved standard plan set:
No
I think my project qualifies as subject-to-field-inspection or a DADU standard plan:
No
I am requesting a pre-submittal conference:
No
I have a vacant building on the record site address:
No
PERMIT APPLICATION COMMON
Where on your property are you working?:
THE PROJECT WILL OCCUPY THE ENTIRE SITE
Is work in the right-of-way (street or alley) required?:
Yes
Choose the Primary Property Use:
Multifamily
Project Value:
51000000
FLOATING RESIDENCE INFO
Is this building a Floating Residence?:
No
LAND USE STREET ELEMENTS
Number of Curb Cuts for This Permit:
0
PARKING
Number of Existing Onsite Parking Spaces:
4
Number of Proposed Onsite Parking Spaces:
22
Number of Existing Bicycle Parking Spots:
0
Number of Proposed Bicycle Parking Spots:
335
GROUND DISTURBANCE
Is your development site in an environmentally critical area (ECA)?:
No
New and Replaced Hard Surface > 750 sq ft?:
Yes
Are you doing more than 750 square feet of earth disturbance?:
Yes
I, the owner or owner's authorized representative of the property referenced in this submission, give the City of Seattle Department of Construction and Inspections permission to conduct a Pre-Application Site Visit. I agree that: 1) electronic filing constitutes an authorizing signature; 2) I will inform all tenants of the site visit prior to the inspection being conducted; and 3) if conditions such as uncontrolled dogs or uncooperative tenants hinder the inspector's ability to conduct the site visit, the site visit will not occur and the site visit fee may be forfeited.:
No
Foundation Type:
Piles
BUILDING CODE INFO
What building code was used for your design?:
2018 SBC
Is this a substantial alteration?:
No
Are you changing the envelope?:
No
Action Type:
New
Number of Existing Building Stories:
1
Number of Existing Below-Grade Building Stories:
0
Number of Proposed Building Stories:
50
Number of Proposed Below-Grade Building Stories:
4
Number of Mezzanines:
1
Is this a high-rise?:
Yes
Will you change the building use or occupancy?:
Yes
Main Existing Use of Building:
Storage
Existing Occupancy:
S-1 Repair Garage Not H-3
Will your application include a new standard plan?:
Yes
FIRE PROTECTION SYSTEMS
Sprinklers Meet NFPA 13:
Yes
Sprinklers Meet NFPA 13R:
No
Partial Fire Protection System:
No
Fire Alarm:
Yes
Other Fire Protection System:
No
ENERGY CODE
Portion of Building Semi-Heated or Unheated:
No
Compliance Category:
Commercial
Is there a commercial kitchen hood exhaust system?:
No
Is there a fume hood?:
No
Is there a spray paint booth?:
No
Describe Mechanical Systems Being Installed (if any):
The apartments will be heated and cooled by a water source VRF system consisting of a fan coil unit in each apartment, refrigerant piping between fan coil units and BCU controller in mechanical room, refrigerant piping between BCU controller and VRF water source module, condenser water piping between VRF water source module (one per floor) and heating boilers/fluid cooler. The apartments will be ventilated by ERV (energy recovery ventilators). One per apartment. The corridors will be pressurized by a packaged, rooftop air handling unit. The garage will be ventilated by exhaust fans, supply fans, transfer fans and controlled by CO gas sensors. The stairs and elevators will be pressurized to maintain pressure differentials during fire alarm. For emergency generator, we will install radiator exhaust duct, intake air, engine exhaust piping, fuel fill piping between fuel fill station and subbase tank, vents form subbase tank. Ventilation of SCL vault Ventilation of miscellaneous common area rooms.